HTS-LM06X Series Submersible Temperature and Level Transmitter
    Publish time 2026-06-25 09:49    

HTS-LM06X Series Submersible Temperature and Level Transmitter is based on the principle that the static pressure of the measured liquid is proportional to its height. It utilizes the piezoresistive effect of diffused silicon or ceramic sensing elements to convert static pressure into an electrical signal. The built-in PT100 temperature sensor can simultaneously measure the liquid temperature. Combined with dedicated digital circuitry, and after signal processing including signal amplification, linear compensation, interference suppression, and surge protection, it becomes an integrated product capable of simultaneously measuring liquid level and temperature.


HTS-LM06X Series Submersible Temperature and Level Transmitter

HTS-LM06X Series Submersible Temperature and Level Transmitter is based on the principle that the static pressure of the measured liquid is proportional to its height. It utilizes the piezoresistive effect of diffused silicon or ceramic sensing elements to convert static pressure into an electrical signal. The built-in PT100 temperature sensor can simultaneously measure the liquid temperature. Combined with dedicated digital circuitry, and after signal processing including signal amplification, linear compensation, interference suppression, and surge protection, it becomes an integrated product capable of simultaneously measuring liquid level and temperature.

Features

l  Multiple output signals available

l  All-welded construction, durable

l  Anti-interference and surge protection

l  Lightning protection, compliant with IEC61000-4-5/Level-4 standards


Application

It is suitable for measuring groundwater, geothermal wells, agricultural irrigation, meteorological monitoring, disaster prevention systems, and liquid level and temperature measurement and control.

Range

01300mH2O; -20℃…100

Pressure   Form

Gauge   pressure (G); Sealed gauge pressure (S); Absolute pressure (A)

Output   Signal

420mA (dual-channel); IIC;   RS485

Input   voltage

830VDC; 58VDC; 3.3VDC

Accuracy level

0.1%FS

0.2%FS

0.5%FS

Zero Drift

0.01%FS/

0.02%FS/

0.05%FS/

Sensitivity Drift

0.01%FS/

0.02%FS/

0.05%FS/

Compensation   Temperature

050; -1070

Working   Temperature

-20+85; -40+125

Storage   Temperature

-40+125

Long-term   Stability

0.2±%FS/year; 0.5±%FS/year

Response   Time

1ms

Overload   Capacity

200%

Load   Resistor

R=(U-12.5)/0.02-RD 

Note:   U is the power supply voltage, and RD is the internal resistance of the power   supply.

Measuring   Medium

Corrosive   media compatible with 316L

Diaphragm   Material

316L;   Tantalum; C-276; TC4; A1203

Shell   Material

304SS;   316L; TC4

Electrical   Interface

Direct   outgoing line

Process   Interface

//

Protection   level

IP68

Explosion-proof   rating

Ex   ia   CT6 optional